  600 Volt Control Cables: [ 600V Control Cable: Foil Shield, FEP (200°C) ] (Color Code Chart)
Stranded. M16878/11 Type K Inners. 200°C Jacket.
 
 
AWG 16 (19x29) Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1236
2
.012
.015
.188
34
1336
3
.012
.015
.200
44
1436
4
.012
.015
.220
54
1636
6
.012
.015
.265
75
1736
7
.012
.015
.265
84
1936
9
.012
.015
.342
107
1136
12
.012
.015
.354
136
           
AWG 14 (19x27) Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1226
2
.012
.015
.216
49
1326
3
.012
.015
.230
63
1426
4
.012
.015
.253
79
1626
6
.012
.015
.307
109
1726
7
.012
.015
.307
124
1926
9
.012
.015
.398
156
1126
12
.012
.015
.412
199
           
AWG 12 (19x25) Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1216
2
.012
.015
.250
71
1316
3
.012
.015
.266
93
1416
4
.012
.015
.294
116
1616
6
.012
.015
.358
162
1716
7
.012
.015
.358
183
1916
9
.012
.015
.466
231
1116
12
.012
.015
.482
296
           
AWG 10 (37x26) Tinned Copper
Aero P/N # of Cond. Insulation Thickness (inches) Jacket Thickness (inches) Jacket O.D. (inches) Lbs / 1000'
1206
2
.012
.015
.302
105
1306
3
.012
.015
.322
139
1406
4
.012
.015
.357
172
1606
6
.012
.015
.436
241
1706
7
.012
.015
.436
273
1906
9
.012
.015
.570
344
1106
12
.012
.015
.590
442
           
 
Specifications

Conductor:
Stranded TC

Insulation:
FEP (200°C)

Color Code:
Chart 1

Shield:
Aluminum/Mylar and Drain

Jacket:
FEP (200°C)

Impedance:
(AWG 16) 49 Ohms Nom.
(AWG 14) 43 Ohms Nom.
(AWG 12) 39 Ohms Nom.
(AWG 10) 33 Ohms Nom.

Vel. of Propagation:
69% Nom.

Capacitance:
(AWG 16) 30 pF/FT Nom.
(AWG 14) 34 pF/FT Nom.
(AWG 12) 38 pF/FT Nom.
(AWG 10) 45 pF/FT Nom.

Voltage:
Spark tested @ 5 KV for use as 600 Volts Control

Temperature Rating:
-80°C to +200°C
(Insulation & Jacket only)

Note:
TC conductors are rated 150°C

Put Ups:
1000 Feet (+/- 10%)
(Available in Bulk Reels)