AWG
16 (19x29) Tinned Copper
|
| Aero
P/N |
#
of Cond. |
Insulation
Thickness (inches) |
Jacket
Thickness (inches) |
Jacket
O.D. (inches) |
Lbs
/ 1000' |
1238 |
2 |
.012 |
.025 |
.232 |
44 |
1338 |
3 |
.012 |
.025 |
.244 |
56 |
1438 |
4 |
.012 |
.025 |
.264 |
68 |
1638 |
6 |
.012 |
.025 |
.309 |
92 |
1738 |
7 |
.012 |
.025 |
.309 |
99 |
1938 |
9 |
.012 |
.025 |
.386 |
129 |
1138 |
12 |
.012 |
.025 |
.398 |
163 |
| |
|
|
|
|
|
AWG
14 (19x27) Tinned Copper |
|
| Aero
P/N |
#
of Cond. |
Insulation
Thickness (inches) |
Jacket
Thickness (inches) |
Jacket
O.D. (inches) |
Lbs
/ 1000' |
1228 |
2 |
.012 |
.025 |
.260 |
58 |
1328 |
3 |
.012 |
.025 |
.274 |
74 |
1428 |
4 |
.012 |
.025 |
.297 |
91 |
1628 |
6 |
.012 |
.025 |
.351 |
128 |
1728 |
7 |
.012 |
.025 |
.351 |
142 |
1928 |
9 |
.012 |
.025 |
.442 |
176 |
1128 |
12 |
.012 |
.025 |
.476 |
222 |
| |
|
|
|
|
|
AWG
12 (19x25) Tinned Copper |
|
| Aero
P/N |
#
of Cond. |
Insulation
Thickness (inches) |
Jacket
Thickness (inches) |
Jacket
O.D. (inches) |
Lbs
/ 1000' |
1218 |
2 |
.012 |
.025 |
.294 |
77 |
1318 |
3 |
.012 |
.025 |
.310 |
100 |
1418 |
4 |
.012 |
.025 |
.338 |
129 |
1618 |
6 |
.012 |
.025 |
.402 |
179 |
1718 |
7 |
.012 |
.025 |
.402 |
199 |
1918 |
9 |
.012 |
.025 |
.510 |
248 |
1118 |
12 |
.012 |
.025 |
.526 |
314 |
| |
|
|
|
|
|
AWG
10 (37x26) Tinned Copper |
|
| Aero
P/N |
#
of Cond. |
Insulation
Thickness (inches) |
Jacket
Thickness (inches) |
Jacket
O.D. (inches) |
Lbs
/ 1000' |
1208 |
2 |
.012 |
.025 |
.346 |
107 |
1308 |
3 |
.012 |
.025 |
.366 |
140 |
1408 |
4 |
.012 |
.025 |
.401 |
178 |
1608 |
6 |
.012 |
.025 |
.480 |
243 |
1708 |
7 |
.012 |
.025 |
.480 |
281 |
1908 |
9 |
.012 |
.025 |
.616 |
352 |
1108 |
12 |
.012 |
.025 |
.634 |
449 |
| |
|
|
|
|
|
| |
|
| Specifications |
|
| Conductor:
Stranded TC
Insulation:
FEP
Color Code:
Chart 1
Shield:
90% TC Braid
Jacket:
FEP (200°C)
Impedance:
(AWG 16) 49 Ohms Nom.
(AWG 14) 43 Ohms Nom.
(AWG 12) 39 Ohms Nom.
(AWG 10) 33 Ohms Nom.
Vel. of Propagation:
69% Nom.
|
Capacitance:
(AWG 16) 30 pF/FT Nom.
(AWG 14) 34 pF/FT Nom.
(AWG 12) 38 pF/FT Nom.
(AWG 10) 45 pF/FT Nom.
Voltage:
Spark tested @ 5 KV for use as 600 Volts Control
Temperature Rating:
-80°C to +200°C
(Insulation & Jacket only)
Note:
TC conductors are rated 150°C
Put Ups:
1000 Feet (+/- 10%)
(Available in Bulk Reels) |