| AWG 
                          20 (7x28) Tinned Copper |  | 
                     
                      | Aero 
                        P/N | # 
                        of Pair | Insulation 
                        Thickness (inches) | Jacket 
                        Thickness (inches) | Jacket 
                        O.D. (inches) | Lbs 
                        / 1000' | 
                     
                      | 2240 | 2 | .006 | .010 | .199 | 28 | 
                     
                      | 2340 | 3 | .006 | .010 | .212 | 37 | 
                     
                      | 2440 | 4 | .006 | .010 | .234 | 47 | 
                     
                      | 2540 | 5 | .006 | .010 | .264 | 57 | 
                     
                      | 2640 | 6 | .006 | .012 | .278 | 68 | 
                     
                      | 2740 | 7 | .006 | .012 | .278 | 77 | 
                     
                      | 2840 | 8 | .006 | .012 | .308 | 87 | 
                     
                      | 2940 | 9 | .006 | .012 | .328 | 97 | 
                     
                      | 2040 | 10 | .006 | .012 | .353 | 107 | 
                     
                      | 2140 | 12 | .006 | .012 | .368 | 126 | 
                     
                      | 2140-15 | 15 | .006 | .015 | .404 | 158 | 
                     
                      | 2140-18 | 18 | .006 | .015 | .434 | 187 | 
                     
                      | 2140-20 | 20 | .006 | .015 | .444 | 206 | 
                     
                      | 2140-25 | 25 | .006 | .015 | .514 | 254 | 
                     
                      | 2140-30 | 30 | .006 | .015 | .544 | 302 | 
                     
                      |  |  |  |  |  |  | 
                  
                  
                     
                      | AWG 
                          18 (7x26) Tinned Copper |  | 
                     
                      | Aero 
                        P/N | # 
                        of Pair | Insulation 
                        Thickness (inches) | Jacket 
                        Thickness (inches) | Jacket 
                        O.D. (inches) | Lbs 
                        / 1000' | 
                     
                      | 2230 | 2 | .006 | .010 | .234 | 37 | 
                     
                      | 2330 | 3 | .006 | .010 | .250 | 50 | 
                     
                      | 2430 | 4 | .006 | .012 | .280 | 65 | 
                     
                      | 2530 | 5 | .006 | .012 | .316 | 79 | 
                     
                      | 2630 | 6 | .006 | .012 | .328 | 92 | 
                     
                      | 2730 | 7 | .006 | .012 | .328 | 104 | 
                     
                      | 2830 | 8 | .006 | .012 | .364 | 118 | 
                     
                      | 2930 | 9 | .006 | .015 | .394 | 135 | 
                     
                      | 2030 | 10 | .006 | .015 | .424 | 149 | 
                     
                      | 2130 | 12 | .006 | .015 | .442 | 175 | 
                     
                      | 2130-15 | 15 | .006 | .015 | .478 | 214 | 
                     
                      | 2130-18 | 18 | .006 | .015 | .514 | 253 | 
                     
                      | 2130-20 | 20 | .006 | .015 | .526 | 279 | 
                     
                      | 2130-25 | 25 | .006 | .015 | .610 | 345 | 
                     
                      | 2130-30 | 30 | .006 | .015 | .646 | 410 | 
                     
                      |  |  |  |  |  |  | 
                  
                  
                    
                     
                      
                    
                     
                      |  |  | 
                     
                      | Specifications |  | 
                     
                      | Conductor:Stranded T.C.
 Insulation:FEP or
 Halar (ECTFE) Add "HL" to P/N
 Color Code:Chart 3
 Shield:Aluminum/Mylar
 Jackets Available:FEP (200°C) or
 PVDF (150°C) Add "K" to P/N or
 Plenum PVC Jacket available
 Industry Approvals:NEC Article 725-CL2P or
 NEC Article 800-CMP
 PCC FT6-C(UL) (CMP only)
 |  Impedance: (FEP only)(AWG 18) 72 Ohms Nom.
 (AWG 20) 78 Ohms Nom.
 Vel. of Propagation: (FEP only)69% Nom.
 Capacitance: (FEP only)(AWG 18) 20.5 pF/ft Nom.
 (AWG 20) 19.1 pF/ft Nom.
 Operating Temperature Range:-80°C to +200°C (FEP/FEP)
 -20°C to +150°C (FEP/PVDF)
 -5°C to +75°C (Halar/Aeroflex)
 Put Ups:1000 Feet (+/- 10%)
 (Available in Bulk Reels)
 |