| AWG 
                          12 (19x.0185") Tinned Copper |  | 
                     
                      | Aero 
                        P/N | # 
                        of Cond. | Insulation 
                        Thickness (inches) | Jacket 
                        Thickness (inches) | Jacket 
                        O.D. (inches) | Lbs 
                        / 1000' | 
                     
                      | 1210 | 2 | .006 | .010 | .216 | 64 | 
                     
                      | 1310 | 3 | .006 | .010 | .230 | 84 | 
                     
                      | 1410 | 4 | .006 | .010 | .255 | 104 | 
                     
                      | 1510 | 5 | .006 | .012 | .287 | 126 | 
                     
                      | 1610 | 6 | .006 | .012 | .316 | 147 | 
                     
                      | 1710 | 7 | .006 | .012 | .316 | 167 | 
                     
                      | 1810 | 8 | .006 | .012 | .418 | 193 | 
                     
                      | 1910 | 9 | .006 | .015 | .418 | 213 | 
                     
                      | 1010 | 10 | .006 | .015 | .418 | 233 | 
                     
                      | 1110-12 | 12 | .006 | .015 | .432 | 273 | 
                     
                      | 1110-15 | 15 | .006 | .015 | .485 | 335 | 
                     
                      | 1110-18 | 18 | .006 | .015 | .514 | 395 | 
                     
                      | 1110-20 | 20 | .006 | .015 | .544 | 436 | 
                     
                      | 1110-25 | 25 | .006 | .015 | .610 | 537 | 
                     
                      | 1110-30 | 30 | .006 | .015 | .650 | 638 | 
                     
                      |  |  |  |  |  |  | 
                  
                  
                     
                      | AWG 
                          10 (37x26) Tinned Copper **For Audio Only** |  | 
                     
                      | Aero 
                        P/N | # 
                        of Cond. | Insulation 
                        Thickness (inches) | Jacket 
                        Thickness (inches) | Jacket 
                        O.D. (inches) | Lbs 
                        / 1000' | 
                     
                      | 1200 | 2 | .006 | .012 | .288 | 101 | 
                     
                      | 1300 | 3 | .006 | .012 | .307 | 129 | 
                     
                      | 1400 | 4 | .006 | .012 | .341 | 166 | 
                     
                      | 1500 | 5 | .006 | .015 | .385 | 200 | 
                     
                      | 1600 | 6 | .006 | .015 | .399 | 233 | 
                     
                      |  |  |  |  |  |  | 
                  
                  
                    
                     
                      
                    
                     
                      |  |  | 
                     
                      | Specifications |  | 
                     
                      | Conductor:Stranded T.C.
 Insulation:FEP
 Color Code:Chart 1
 Shield:Aluminum/Mylar
 Jackets Available:FEP (200°C) or
 Fluorocopolymer (150°C) Add "K" to P/N 
                          or
 Plenum PVC Jacket available
 | Industry Approvals:NEC Article 725-CL2P
 Vel. of Propagation: (FEP only)69% Nom.
 Temperature Rating:-80°C to +200°C (FEP/FEP)
 -40°C to +150°C (FEP/E-CTFE)
 Put Ups:1000 Feet (+/- 10%)
 (Available in Bulk Reels)
 |